Description
Details
Branches of Use
- Nuclear power industry
 - Metallurgy
 - Radiological laboratories
 - Radioactive waste storage sites
 - Medical
 
Purpose of Use
- Display of measurement results of ambient dose equivalant rate (DER) of gamma radiation abtained from BDBG-09 detecting unit of gamma radiation.
 - Audio and light alarming when threshold level of gamma radiation DER exceeded.
 
Specifications:
- DER display range – 0.01… 107 µSv/h.
 - Number of digits for DER display – three.
 - Three threshold levels programming in the range of 0.01 µSv/h to 9.99 Sv/h with 0.01 µSv/h discreteness.
 - Signaling when threshold levels exceeded – audio (with different soundings for each threshold level), and light (color change of DER measurement display).
 - Operation in the network through the RS-485 interface.
 - Power supply from industrial network (220 V) through the power adapter.
 - Operating mode – 24-hour continuous.
 - Distance between the panel and the detecting unit – from 0.5 to 50 m.
 - Dimensions – not more than 345x135x40 mm.
 - Weight (without the power adapter) – 1.0 kg.
 - Mounting method – upright wall-mounted.
 





 
 
 
 



 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 



 




