Description
Details
It is a frequency counter that measures signals over a wide range of 0.01 Hz to 2.4 GHz. Equipped with gate time that is continuously varying from 100ms to 10s and a maximum power consumption of only 5W.
All functions depend on a single CPU. It has a crystal-controlled temperature circuit that provides a constant compensation for temperature change, reduces the measurement errors. Its channel B (CH.B) input provides an attenuator (x1, x20) and an AC/DC coupling.
FEATURES:
- With 3 steps function selection: work state, unit & 8-digit LED display
 - Provides frequency measurement from 0.01Hz to 2.4GHz
 - Provides cyclic measurement range from 0.5ms to 10s
 - With attenuation of 20dB and input impedance of 1MO
 - With frequency, period and equal-precision measurement
 - The machine can switch from 110V to 220V (vise versa)
 - Maximum power consumption is only 5W
 
 SPECIFICATIONS:
- 8 digit LED display
 - 3 step function selections
 - Channel B (CH. B) input has an attenuator (x1, x20)
 - AC/DC coupling for low-pass filter
 - All functions depend on a single CPU
 - Crystal-controlled temperature circuit
 - 2 Input Channels : Channel A for 0.01 Hz to 50 MHz ; Channel B for 50 MHz to 2.4 GHz
 - Channel A (0.01Hz to 50 MHz)
- Frequency range : DC couple 0.01 Hz to 100 Hz ; AC couple 100 Hz to 50 MHz
 - Sensitivity :
- "DC" 0.01 Hz - 1 Hz = 500m Vp-p , 1 Hz - 100Hz = 80m Vrms
 - "AC" 100 Hz - 50 M Hz = 80m Vrms
 
 - Input impedance : 1 MΩ
 
 - Channel B (50 MHz to 2.4 GHz)
- Frequency : 50 MHz - 2.4 GHz
 - Sensitivity :
- 50 MHz - 1.2 GHz = 80m Vrms
 - 1.2 GHz - 2.4 GHz > 80m Vrms
 
 - Coupling : AC only
 - Input Impedance : 50Ω
 
 - Resolution depends on gate time control setting
 - Time base:
- Short time stability : ± 3 x 10-9 per second
 - Long time stability : ± 2 x 10-8 per mon
 - Temperature drift coefficient : ± 1 x 10-7, 10°C - 40°C
 - Line voltage variation : ± 1 x 10-7 for line voltage ± 10
 
 - Gate Time : Continuously variable from 100ms to 10s
 - Precision : standard time error (t) x frequency (f) ±1d
 - Power supply : 110V & 220V
 - Power cord (Available for US, UK, Australian & European system)
 - Preheat time : 20 minutes
 - Operating environment : 0°C - 50°C, 10 - 90% R.H.
 - Dimension : approx. 270 x 215 x 100 mm
 - Weight : approx. 1.6 kg
 
SET INCLUDES:
- Set includes:
 - 1 x Frequency Counter
 - Power Cord (Available for US, UK, Australian & European system)
 - English User Manual
 - Test probe with BNC type connecto
 









 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 



 